In order to configure the system to estimate and calculate the vessel’s correct bunker consumption by using the correct bunker type(s), some changes need to be done in Vessel Administration to the Masterdata - Dataloy Property.
Definitions:
FO = High Sulphur Fuel Oil e.g. RMG380 3.5% sulphur
FOLS = Low Sulphur Fuel Oil e.g. RMG380 0.5% sulphur
DO = Diesel Oil / Gas Oil e.g. DMA
DOLS = Low Sulphur Diesel Oil / Gas Oil e.g. DMA 0.1% sulphur
For vessels burning FO and DO outside ECA, and DOLS inside ECA.
This is the default estimation scheme, and is used if nothing else is configured.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FO | DOLS |
Aux (DO at Sea) | DO | DOLS |
Boilers | FO | DOLS |
Generators (FO in port) | FO | DOLS |
Generators (DO in port) | DO | DOLS |
Heating (tank only) | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS |
For vessels burning FO and DOLS outside ECA, and DOLS inside ECA.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FO | DOLS |
Aux (DO at Sea) | DOLS | DOLS |
Boilers | FO | DOLS |
Generators (FO in port) | FO | DOLS |
Generators (DO in port) | DOLS | DOLS |
Heating (tank only) | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS |
For vessels burning DOLS on all engines inside and outside ECA.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | DOLS | DOLS |
Aux (DO at Sea) | DOLS | DOLS |
Boilers | DOLS | DOLS |
Generators (FO in port) | DOLS | DOLS |
Generators (DO in port) | DOLS | DOLS |
Heating (tank only) | DOLS | DOLS |
Tank Cleaning (tank only) | DOLS | DOLS |
For vessels burning FO outside ECA, FOLS inside ECA, and DOLS on aux engines.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FO | FOLS |
Aux (DO at Sea) | DOLS | DOLS |
Boilers | FO | DOLS |
Generators (FO in port) | FO | DOLS |
Generators (DO in port) | DOLS | DOLS |
Heating (tank only) | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS |
For vessel burning FO outside ECA, and FOLS inside ECA on the main engine. On aux engines, this scheme estimates DO outside ECA and DOLS inside ECA.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FO | FOLS |
Aux (DO at Sea) | DO | DOLS |
Boilers | FO | DOLS |
Generators (FO in port) | FO | DOLS |
Generators (DO in port) | DO | DOLS |
Heating (tank only) | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS |
For vessels only burning FOLS both inside and outside ECA on the mail engine. On aux engines, this scheme estimates DOLS only.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FOLS | FOLS |
Aux (DO at Sea) | DOLS | DOLS |
Boilers | FOLS | FOLS |
Generators (FO in port) | FOLS | FOLS |
Generators (DO in port) | DOLS | DOLS |
Heating (tank only) | FOLS | FOLS |
Tank Cleaning (tank only) | FOLS | FOLS |
For vessels fitted with an Exhaust Gas Scrubber.
For closed loop scrubber this scheme estimates Fuel Oil (FO) on Main Engine, both inside and outside ECA, “at sea” and “in port”.
For open loop scrubber DOLS will be used in Open Loop Restricted Areas.
Configuration:
Outside ECA | Inside ECA | |
---|---|---|
Main Engine | FO | FO |
Aux (DO at Sea) | DO | DOLS |
Boilers | FO | DOLS |
Generators (FO in port) | FO | DOLS |
Generators (DO in port) | DO | DOLS |
Heating (tank only) | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS |
Open Loop Scrubber
Outside ECA Outside OLRA | Inside ECA | Outside ECA Inside OLRA | Inside ECA Inside OLRA | |
---|---|---|---|---|
Main Engine | FO | FO | FO | DOLS |
Aux (DO at Sea) | DO | DOLS | DO | DOLS |
Boilers | FO | DOLS | FO | DOLS |
Generators (FO in port) | FO | DOLS | FO | DOLS |
Generators (DO in port) | DO | DOLS | DO | DOLS |
Heating (tank only) | FO | DOLS | FO | DOLS |
Tank Cleaning (tank only) | FO | DOLS | FO | DOLS |